High Quality Electronic Product supplier in Abu Dhabi

Fluke 87V TRMS Industrial Multimeter

Key features

The Fluke 87V industrial digital multimeter provides the resolution and accuracy to efficiently troubleshoot motor drives, plant automation, power distribution, and electromechanical equipment.

  • Safer and rugged: Safety rated CAT III 1000 V, CAT IV 600 V
  • Accurate: Measure current, voltage and frequency on complex variable frequency drive (VFD) signals
  • This electrical multimeter correctly measure pulse-width modulated motor drive signals
  • Save time: The 87V multimeter includes a built-in thermometer and temperature probe
  • True-RMS AC voltage and current for measuring non-linear signals

Request For Quote


Description

Specifications: Fluke 87V TRMS Industrial Multimeter

Specifications
Voltage DC Maximum voltage 1000 V
Accuracy ±(0.05% + 1)
Maximum resolution 10 µV
Voltage AC Maximum voltage 1000 V
Accuracy ±(0.7% + 2) True RMS
AC bandwidth 20 kHz with low pass filter; 3 dB @ 1 kHz
Maximum resolution 0.1 mV
Current DC Maximum amps 10 A (20 A for 30 seconds maximum)
Amps accuracy ±(0.2% + 2)
Maximum resolution 0.01 µA
Current AC Maximum amps 10 A (20 A for 30 seconds maximum)
Amps accuracy ±(1.0% + 2) True RMS
Maximum resolution 0.1 µA
Resistance Maximum resistance 50 MΩ
Accuracy ±(0.2% + 1)
Maximum resolution 0.1 Ω
Capacitance Maximum capacitance 9,999 µF
accuracy ±(1% + 2)
Maximum resolution 0.01 nF
Frequency Maximum frequency 200 kHz
Accuracy ±(0.005% + 1)
Maximum resolution 0.01 Hz
Duty cycle Maximum duty cycle 99.9%
Accuracy ±(0.2% per kHz + 0.1%)
Maximum resolution 0.1%
Temperature measurement –200.0 °C – 1090 °C
–328.0 °F – 1994.0 °F
excluding probe
80 BK temperature probe –40.0 °C – 260 °C
–40.0 °F – 500 °F, 2.2 °C or 2% whichever is greater
Conductance Maximum conductance 60.00 nS
Accuracy ±(1.0% + 10)
Maximum resolution 0.01 nS
Diode Range 3 V
Resolution 1 mV
Accuracy ±(2% + 1)
Duty cycle range Accuracy Within ±(0.2% per kHz + 0.1%)
Environmental Specifications
Operating temperature –20 °C to + 55 °C
Storage temperature –40 °C to + 60 °C
Humidity (without condensation) 0% – 90% (0 °C – 35 °C)
0% – 70% (35 °C – 55 °C)
Operating Altitude 2000 m
Safety Specifications
Overvoltage category EN 61010–1 to 1000 V CAT III, 600V CAT IV
Agency approvals CE, CSA, RCM
Mechanical and General Specifications
Size 201 x 98 x 52 mm (with holster)
Weight 355 g
624 g – with holster
Display Digital 6000 counts updates 4/sec.
19,999 counts in high–resolution mode
Analog 32 segments, updates 40/sec
Frequency 19,999 counts, updates 3/sec at > 10 Hz
Warranty Lifetime
Battery Life Alkaline ~400 hours typical, without backlight
Shock 1 Meter drop per IEC 61010–1:2001
Vibration Per MIL–PRF–28800 for a Class 2 instrument

Brand

Fluke

Praesent sapien massa, convallis a pellentesque nec, egestas non nisi. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Vivamus magna justo, lacinia eget consectetur sed, convallis at tellus. Pellentesque in ipsum id orci porta dapibus. Quisque velit nisi, pretium ut lacinia in, elementum id enim. Quisque velit nisi, pretium ut lacinia in, elementum id enim.